The tekmarNet® 4 Timer 033 provides a programmable setback schedule for an entire tekmarNet® system. It maintains time and communicates up to 4 schedules on the network that up to 96 tekmarNet® thermostats can follow. This product can also be used in stand alone applications.
2 or 4 event schedules
Battery-less backup
CSA and C US Approved for use in USA and Canada
Daylight savings time
Provides a setback schedule for all network devices
Relay contact to signal other devices of setback
Up to 4 independent programmable schedules available
tekmarNet® 4 and tekmarNet® 2 compatible
Control | Microprocessor-based. This is not a safety (limit) device |
Packaged weight | 0.5 lb (230 g) |
Dimensions | 2-7/8" H x 2-7/8" W x 13/16" D (73 x 73 x 21 mm) |
Enclosure | White PVC plastic, NEMA type 1 |
Approvals | CSA C US, meets Class B: ICES & FCC Part 15 |
Ambient conditions | Indoor use only, 32 to 122°F (0 to 50°C), RH ≤92% to 104°F (40°C), and 50% above 104°F (40°C), Altitude <9840 ft. (3000 m), Pollution Degree 2 |
Power supply | 24 V (ac) ± 10%, 50/60 Hz, 2.7 VA, NEC / CEC Class 2 |
Relay | 24 V (ac) 2 A |
Warranty | Limited 3 Year Warranty |
In most cases the current version of literature will work, otherwise use the piece of literature most closely matching the date code of your product.
Product Submittal |
Jan 2011 - Present |
|
Installation & Operation Manual |
Oct 2007 - Present |
|
Job Record |
Aug 2009 - Present |
|
User Manual |
Oct 2007 - Present |
|
Wiring Brochure |
Oct 2007 - Present |
Boiler Control
256
Boiler Control
260
Boiler Control
261
Boiler Control
263
Boiler Control
265
Boiler Control
268
Mixing Control
356
Mixing Control
360
Mixing Control
361
Mixing Control
362
Universal Reset Control
363
tN2 House Control
400
tN2 House Control
401
tN2 House Control
402
tN2 House Control
403
tN2 House Control
406
tekmarNet© Internet Gateway 485